SEW變頻器MOVITRAC-31C系列故障代碼詳表

發布時間:2019-08-02 15:40:26來源:

故障代碼 故障現象/類型 故障原因 解決對策
1 Overcurrent Short circuit/earth fault at the output. Motor too large. Faulty output stage. Remove short-circuit. Connect smaller motor. If fault can still not be reset, contact SEW service.
2 DC link voltage DC link voltage too high. Increase deceleration ramps.
3 Brake chopper Regenerative power too high Braking resistor circuit interrupted Short-circuit in the braking resistor circuit Braking resistance value too high Faulty brake chopper Increase deceleration ramps. Check connecting leads of the braking resistor. Check technical data of the braking resistor. Exchange MOVITRAC® 31C
5 Regenerative overload With active regen. n monit. (P520/P522) and speed control (P770): faulty encoder signals wrong number of pole pairs (P324/P344) value of increments (P773) not correct Check encoder. Check encoder connection. Set number of pole pairs correctly. Set value of increments correctly.
4 Cont. overload ´t utilization too high (> 125(%)). Reduce load.
6 Overtemperature Thermal overload of the inverter. Reduce load and / or ensure adequate cooling.
7 Phase failure With active mains volt. monitor.(P530) Phase missing at TL. X1:1/2/3. Check mains supply.
10 Direction of rotation Only with active speed control (P770): Encoder tracks A/A and B/B are swapped in pairs. Motor rotates in opposite direction. Regen. overload (i.e. with sagging hoist) because of excessive load or BOOST setting too low (P321/P341). Check encoder connection. Exchanging two motor phases. Reduce load or increase BOOST.
11 Speed detection Only with active speed control (P770): Faulty encoder connection. FEN31C/FPI31C option not installed. Check encoder connection. Insert correct option (FEN31C or FPI31C).
12 Mot. overload With active n monit. (P510/P512) and speed control (P770): faulty encoder signals wrong number of pole pairs (P324/P344) value of increments (P773) not correct Check encoder. Check encoder connection. Set number of pole pairs correctly. Set value of increments correctly.
13 Starting conditions With active hoist function (P710/P712): Current too low during the premagnetization phase: Motor rated power selected too small in relation to the inverter rated power. Cross-section of the motor leads too small. Check startup data and carry out new startup if necessary. Check inverter-motor connection. Check cross-section of the motor leads and increase if necessary.
14 Output open With active hoist function (P710/P712): Two or all output phases interrupted. Motor rated power selected too small in relation to the inverter rated power. Check inverter-motor connection. Check startup data and carry out new startup if necessary.
17 Stack overflow Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
18 Stack underflow Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
19 NMI trap Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
20 Undefined opcode Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
21 Protected instr. Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
22 Word op. access Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
23 nstruct. access Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly,
24 Ext. bus access Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.

故障代碼 故障現象/類型 故障原因 解決對策
25 EEPROM Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
26 No connection Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
27 Ext. terminal External fault signal has appeared at a programmable input Eliminate the cause of the fault. Reprogram the terminal, if necessary
28 Fault INTERBUS FFI31C and control mode (P841) = Fieldbus: Faulty monitoring signal. Check Fieldbus connection.
32 Copying Only when copying the parameters (P820): Break or interference in PC or FBG31C connection. Check connection between inverter and PC. Remove FBG31C keypad and plug again.
33 Master-slave Connection master-slave is interrupted. 0V5 connection (RS-485) missing Master or slave defined incorrectly in P880. Check master-slave connection. 0V5-establish connection between master and slave Set P880 correctly.
34 Fieldbus timeout No communication between master and slave within the specified time of the response monitoring. Check communication routine of the master. Increase fieldbus timeout time (P571)/ deactivate monitoring.
35 Connection Encoder-FRS Encoder connection faulty. Power supply of the encoder faulty. Check encoder connection. Check power supply of the encoder.
36 Connection Master-slave Only with FRS and cable break master-slave (P557) = YES: Setpoint connection of slave (TL. 98-101) is disrupted. Master Speed 0 ® slave FRS CTRL is disrupted. Slave FRS CTRL input not assigned. Master Speed 0 output not assigned. No master inverter available. Encoder < 512 pulses per revolution used. Check installation. Check programming of the binary inputs and binary outputs. Check if encoder type is correct.
37 FRS RAM fault Internal fault. If fault occurs repeatedly, contact SEW service.
38 FRS process data fault Fault on interface between inverter and FRS. If fault occurs repeatedly, contact SEW service.
39 FRS parameter data fault Invalid value for FRS parameters (P55_). Check parameter settings.
41 FRS lag fault Polarity of the encoder not set correctly. Acceleration ramps too short. P-gain of the positioning controller too small Speed controller not set property. Value for lag error tolerance too small Change polarity of encoder. Increase ramps. Increase P-gain. Select new parameters for speed controller. Increase lag error tolerance (P551). Check wiring of encoder, motor and mains phases. Check if mechanical system is sluggish or whether drive hit an obstacle.
43 Fault binary output Load on TL. X3:61 > 150 mA. Load on the other binary outputs > 50 mA Short circuit on binary output. Capacitive load on binary output. Check installation of the binary outputs.
、、、、、、、長治變頻器維修、、、、信陽變頻器維修、、、,河南鄭州變頻器專業銷售維修中心,技術精湛,質量可靠,價格比較低,信譽保證!變頻器維修電話:15515598858 0371-56700815
用手機看
SEW變頻器MOVITRAC-31C系列故障代碼詳表

拍下二維碼,信息隨身看

試試用手機掃一掃,
在你手機上繼續觀看此頁面。

主站蜘蛛池模板: 色婷婷综合和线在线 | 色综合久久六月婷婷中文字幕 | 一级骚片超级骚在线观看 | 五月亭亭激情五月 | 成 人 黄 色 视频 免费观看 | 久久亚洲国产 | 99久久99热精品免费观看国产 | 国产精品久久网 | 日b视频免费看 | 欧美日韩一区二区高清免费视频 | 一本一道久久 | 国产一级久久免费特黄 | 免费精品国产自产拍在 | 久久久999久久久精品 | 日韩一区二区三区在线观看 | 曰曰啪天天拍视频在线 | 成人欧美一区二区三区视频 | 成人国产精品一级毛片了 | 久久精品99 | 久久99热久久精品在线6 | 成 人国产在线观看高清不卡 | 在线观看精品国产 | 中文字幕视频在线免费观看 | 亚洲精品午夜久久久伊人 | 欧美日韩亚洲精品一区二区三区 | 亚洲综合色视频 | 91久久精品国产免费一区 | 欧美大色网| 777色狠狠一区二区三区 | 久久精品在线 | 在线视频欧美日韩 | 亚洲国产高清精品线久久 | 国产理论视频在线观看 | 啪啪综合网 | 一级免费看片 | 99热久久这里只有精品2010 | 欧美一级欧美一级毛片 | 亚洲天堂欧美 | 国产大陆亚洲精品国产 | 亚洲日本中文字幕在线2022 | 欧美午夜网 |